Laava Pro 12.0
Electrical supply, as published
Heater group 1separate circuit
| Breaker / fuse size | 30 AAs stated by the manufacturer. |
|---|---|
| Minimum wire size | Not stated by manufacturerNot published. Wire sizing depends on run length, ambient temperature, conduit fill, and local code — it is not a lookup from amperage. |
| Current draw | Not stated by manufacturer |
| Voltage / phase | 240 V, 1 ph |
Heater group 2separate circuit
| Breaker / fuse size | 30 AAs stated by the manufacturer. |
|---|---|
| Minimum wire size | Not stated by manufacturerNot published. Wire sizing depends on run length, ambient temperature, conduit fill, and local code — it is not a lookup from amperage. |
| Current draw | Not stated by manufacturer |
| Voltage / phase | 240 V, 1 ph |
Control circuitseparate circuit
| Breaker / fuse size | 15 AAs stated by the manufacturer. |
|---|---|
| Minimum wire size | Not stated by manufacturerNot published. Wire sizing depends on run length, ambient temperature, conduit fill, and local code — it is not a lookup from amperage. |
| Current draw | Not stated by manufacturer |
| Voltage / phase | 120 V |
Core specifications
| Brand | Finnleo |
|---|---|
| Model | Laava Pro 12.0 |
| Series | Laava Pro |
| Rated output | 12 kW |
| Room volume range | 510 ft³ @ 78"; 740 ft³ @ 96" |
| Dimensions | Not stated by manufacturer |
| Rock capacity | max 132 lb (page) |
| Mounting | floor |
Controls, clearances & certification
| Control type | Not stated by manufacturer |
|---|---|
| Control included | Not stated by manufacturerCheck the listing carefully: on several models the control unit is a separate purchase and a significant additional cost. |
| Safety clearances | Not stated by manufacturer |
| Certifications / listings | ETL approved for permanent installations |
| Indoor / outdoor rating | Not stated by manufacturer |
What this manufacturer does not publish
We list these openly because an unpublished specification is itself information — it tells you what to ask the dealer before you buy.
- amperage
- minWireSize
- indoorOutdoorRating
- msrp
Transcription notes
Product number: 1105-120 (1201-17-1). Floor area: 63 sq ft. Manual lists total amps 50 A, breakers 2 × 30 A (heater) + 1 × 15 A (control circuit to contactor box), and wire 4 #8AWG+GR; it does not allocate amperage or wire per group. Single phase heaters are supplied power from two circuits which must be grouped and marked per NEC; system needs a separate 120 volt circuit to power the contactor box.
Where to buy
Sold direct, not through affiliate retailers. We have not found a retailer for this model that runs an affiliate program, so this listing earns us nothing. It is here because the specifications are worth having.
This brand sells through authorized dealers. Find a dealer — an unpaid link.
Coverage here is not conditional on payment.
Sources for this page
Transcribed and checked . Manufacturers revise specifications without notice; the document above is authoritative, not this page.