Finnleo

Laava Pro 10.5

Multi-circuit supplyFull published spec setDirect from vendor only

Electrical supply, as published

Heater group 1separate circuit

Breaker / fuse size30 AAs stated by the manufacturer.
Minimum wire sizeNot stated by manufacturerNot published. Wire sizing depends on run length, ambient temperature, conduit fill, and local code — it is not a lookup from amperage.
Current drawNot stated by manufacturer
Voltage / phase240 V, 1 ph

Heater group 2separate circuit

Breaker / fuse size30 AAs stated by the manufacturer.
Minimum wire sizeNot stated by manufacturerNot published. Wire sizing depends on run length, ambient temperature, conduit fill, and local code — it is not a lookup from amperage.
Current drawNot stated by manufacturer
Voltage / phase240 V, 1 ph

Control circuitseparate circuit

Breaker / fuse size15 AAs stated by the manufacturer.
Minimum wire sizeNot stated by manufacturerNot published. Wire sizing depends on run length, ambient temperature, conduit fill, and local code — it is not a lookup from amperage.
Current drawNot stated by manufacturer
Voltage / phase120 V

Core specifications

BrandFinnleo
ModelLaava Pro 10.5
SeriesLaava Pro
Rated output10.5 kW
Room volume range390 ft³ @ 78"; 600 ft³ @ 96"
DimensionsNot stated by manufacturer
Rock capacitymax 132 lb (page)
Mountingfloor

Controls, clearances & certification

Control typeNot stated by manufacturer
Control includedNot stated by manufacturerCheck the listing carefully: on several models the control unit is a separate purchase and a significant additional cost.
Safety clearancesNot stated by manufacturer
Certifications / listingsETL approved for permanent installations
Indoor / outdoor ratingNot stated by manufacturer

What this manufacturer does not publish

We list these openly because an unpublished specification is itself information — it tells you what to ask the dealer before you buy.

  • amperage
  • minWireSize
  • indoorOutdoorRating
  • msrp

Transcription notes

Product number: 1105-105 (control 1201-17-1). Floor area: 48 sq ft. Manual lists total amps 43.8 A, breakers 2 × 30 A (heater) + 1 × 15 A (control circuit to contactor box), and wire 4 #10AWG+GR; it does not allocate amperage or wire per group. Single phase heaters are supplied power from two circuits which must be grouped and marked per NEC; system needs a separate 120 volt circuit to power the contactor box.

Where to buy

Sold direct, not through affiliate retailers. We have not found a retailer for this model that runs an affiliate program, so this listing earns us nothing. It is here because the specifications are worth having.

This brand sells through authorized dealers. Find a dealer — an unpaid link.

Coverage here is not conditional on payment.

Sources for this page

Transcribed and checked . Manufacturers revise specifications without notice; the document above is authoritative, not this page.